The course will be sent out only after the purchaser fills out the Student Course Assignment Form.
Some of the topics in Book I are applied sprinkler technology, piping materials, piping supports, basic building layout, sprinkler spacing rules, and fundamentals of sprinkler system layout.
6 Modules
Upon completion, the student will receive 21.6 CEUs (216 hours).
Module A Introduction to Applied Sprinkler Technology (36 Hours)
- Lesson 1 Some Basic Things About Your Job as a Sprinkler Designer
- Lesson 2 An Overview of Fire Protection and Fire Protection Sprinkler Systems
- Lesson 3 History and Evolution of the Automatic Fire Sprinkler
- Lesson 4 Types of Systems
Module B Piping Materials (45 Hours)
- Lesson 5 Overhead Piping Materials
- Lesson 6 Piping Materials and Joints
- Lesson 7 Copper Tubing
- Lesson 8 Polybutylene Piping Systems
- Lesson 9 CPVC Plastic Piping Systems
Module C Piping Supports (18 Hours)
- Lesson 10 Hangers and Supports
- Lesson 11 Protection of Piping Subject to Earthquake
Module D Basic Building Layout (36 Hours)
- Lesson 12 Design Drawings and Specifications
- Lesson 13 Construction Types
- Lesson 14 Elements of a Building Layout
- Lesson 15 Drawing of a Background
Module E Sprinkler Spacing Rules (36 Hours)
- Lesson 16 Occupancies and Hazard Classification
- Lesson 17 Standard Sprinkler Spacing
- Lesson 18 Specific Sprinklers – Spacing and Position
- Lesson 19 Other Specific Sprinklers – Spacing, Location, and Position
Module F Fundamentals of Sprinkler System Layout (45 Hours)
- Lesson 20 Layout of Sprinklers
- Lesson 21 Types of System Configurations
- Lesson 22 Preliminary Piping Layout
- Lesson 24 Final Drawings
- Lesson 23 Coordination
5 Modules
Upon completion, the student will receive 18.0 CEUs (180 hours).
Module G Introduction to Calculations (36 Hours)
- Lesson 1 Introduction to Basic Hydraulics
- Lesson 2 Introduction to Water Supplies
- Lesson 3 Water Demand Requirements
- Lesson 4 Pipe Schedule Systems
Module H Advanced Calculations (36 Hours)
- Lesson 5 Hand Calculations to End Sprinkler
- Lesson 6 Hand Calculations – Branch Line to Main
- Lesson 7 Hand Calculations – Main to Source
- Lesson 8 Computer Calculations and Plan Submittal with Calculations
Module I System Types (45 Hours)
- Lesson 9 Wet Systems
- Lesson 10 Antifreeze Systems
- Lesson 11 Dry Pipe Systems
- Lesson 12 Preaction Systems
- Lesson 13 Deluge Systems
Module J Fundamental Materials (36 Hours)
- Lesson 14 Material Takeoff
- Lesson 15 Sleeving
- Lesson 16 Volumes, Surface Areas, Piping Offsets, etc.
- Lesson 17 Drains
Module K Support Systems (27 Hours)
- Lesson 18 Standpipes and Hose Connections
- Lesson 19 Fire Department Pumper Connections and Inspector’s Tests
- Lesson 20 Underground and Backflow
5 Modules
Upon completion, the student will receive 15.3 CEUs (153 hours).
Module L General Information (18 Hours)
- Lesson 1 Codes and Standards
- Lesson 2 Metric Units and Conversions
Module M Pumps and Tanks (18 Hours)
- Lesson 3 Stationary Pumps for Fire Protection
- Lesson 4 Tanks in Fire Protection Design
Module N Storage Design (18 Hours)
- Lesson 5 Storage Criteria
- Lesson 6 Fire Protection Design for Rack Storage Systems
Module O Specialty Systems (63 Hours)
- Lesson 7 Low Expansion Foam Fire Protection
- Lesson 8 Flow Control Systems
- Lesson 9 Exposure Protection
- Lesson 10 Water Spray Systems
- Lesson 11 Special Hazard Fire Suppression Systems: Carbon Dioxide, Clean Agent, Dry Chemical, and Wet Chemical
- Lesson 12 Water Mist
- Lesson 13 Alarm and Detection
Module P Administrative (36 Hours)
- Lesson 14 Inspection and Maintenance
- Lesson 15 Project Management
- Lesson 16 Introduction to Estimating Automatic Fire Sprinkler Systems
- Lesson 17 Contracts, Letter of Proposal, and Change Orders